TAPS™ ODOR CONTROL AIR SCRUBBERS
AS SIMPLE AS IT CAN GET!
Taps™ Scrubbers contain multiple types of media. Two are for oxidizing H2S and other reduced-sulfur compounds. The
third is for nitrogen-based odors and anything else that's left.
Some tailoring is possible. If your odors smell less like rotten eggs (H2S) and more like ammonia or smoke or cooking
grease or petroleum, let us know when you order. We can alter the mix.
You have two scrubbers to choose from:
Model M1 contains 4 cubic feet of media and weighs 200 lbs.; is 21" in diameter and 44" high with a fan (36" high without).
Model M2 contains 7+ cubic feet of media and weighs 365 lbs.; is 24" in diameter and 52" high with a fan (43" high without).
Both are supplied with a custom-molded top, which is shipped with the scrubber and attached during installation. The first installation will probably take several hours; replacement less than ten minutes.
A FAN OR NOT A FAN - IT'S UP TO YOU
If you are exhausting an air relief valve through the scrubber, you don't need a fan. Maybe electrical power isn't available. Your scrubber will still function passively. A word of caution - when you are depending on air being passively displaced (pushed) through the scrubber, you must be sure that all cracks in the enclosed area being scrubbed are well sealed. Otherwise, not all of the foul air may be pushed through the scrubber. Some may leak out the cracks and go untreated.
There are two main advantages to using a fan:
- A fan pulls the air through the scrubber, making it less likely that there will be untreated leaks.
- H2S accumulations eventually form highly corrosive sulfuric acid. When air is constantly evacuated, H2S is not allowed to accumulate, which provides a strong measure of corrosion control.
If you decide to use a fan, it will be shipped with the domed cover shown above and have an eight-foot cord with a grounded plug. We strongly recommend that fans be allowed to run continuously and be speed-controlled to control air flow. Otherwise, be sure to order the 3" PVC gate valve pictured (above right) to control air flow. It is important to move enough air to create a slight vacuum. It is also important to move no more air than is needed because your scrubber will last longer at lower CFM.
You must specify whether your scrubber will be installed indoors or out-of-doors. This will determine which fan is supplied. Both fan motors are 115v, 1 phase, 60Hz, and provide a nominal maximum of 85 CFM on both Models M1 and M2.
|